# enclosure.cfg
################################################################################# ######################### ProForge 5 Enclosure Config ########################## #################################################################################
#config file version v1.0.0 #release date: 17.03.2026
[fan_generic filter_fan] pin: PD12 kick_start_time: 0.250
[fan_generic exhaust_fan] pin: PE5 kick_start_time: 0.250
[fan_generic _chamber_fan] pin: PA8 kick_start_time: 0.250
[heater_generic _chamber_heater] heater_pin: PB11 sensor_pin: PF4 sensor_type: Generic 3950 control: watermark max_power: 1 min_temp: -30 max_temp: 55
[verify_heater _chamber_heater] max_error: 120 check_gain_time: 360 heating_gain: 0.5 hysteresis: 2.0
[gcode_macro SET_CHAMBER] description: Set chamber heater and manage chamber fan overrun gcode: {% set target = params.S|default(0)|float %}
SET_HEATER_TEMPERATURE HEATER=_chamber_heater TARGET={target}
{% if target > 0 %} SET_FAN_SPEED FAN=_chamber_fan SPEED=1.0 UPDATE_DELAYED_GCODE ID=chamber_fan_off DURATION=0 {% else %} UPDATE_DELAYED_GCODE ID=chamber_fan_off DURATION=180 {% endif %}
[gcode_macro CHAMBER_OFF] description: Turn chamber heater off and keep chamber fan on for 3 minutes gcode: SET_HEATER_TEMPERATURE HEATER=_chamber_heater TARGET=0 UPDATE_DELAYED_GCODE ID=chamber_fan_off DURATION=180
[delayed_gcode chamber_fan_off] gcode: SET_FAN_SPEED FAN=_chamber_fan SPEED=0
[gcode_macro TURN_OFF_HEATERS] rename_existing: TURN_OFF_HEATERS_BASE description: Turn off all heaters and keep chamber fan on for 3 minutes gcode: TURN_OFF_HEATERS_BASE UPDATE_DELAYED_GCODE ID=chamber_fan_off DURATION=180